Article ID: 1044
Last updated: 04 Oct, 2016
IssueAt times, threads may seem to hang indefinitely somewhere on the EWS side. Eventually all threads are consumed and syncing stops. CauseUndetermined. ResolutionUse custom options that cause Riva to automatically kill a "hung" thread, restart the service, and report a critical error condition that would send a notification email to the Riva administrator. To implement the solution
If Sync.Crm.WatchDog.MaxCycleLengthSeconds has a value and Sync.Crm.WatchDog.RaiseCriticalErrorWhenTimerExpires is true, Riva kills the hung thread and raises a critical Windows error. If Riva error notification and email notification are enabled, Riva sends a notification email to the designated recipient. Related Knowledge Base Articles
Applies to
Article ID: 1044
Last updated: 04 Oct, 2016
Revision: 11
Views: 6776